
Together with Sigma/ 1 and Sigma/ 2, Sigma/ 3 Motor Diaphragm Metering Pumps compose a continuous product line, covering the capacity ranges from 17 to 1.030 l/h at uniform operation conception, control conception and spare parts management. All three pumps are available as Basic types with no internal electronic control systems or as microprocessor versions for rapid and reliable adjustment to fluctuating dosing tasks.
Advantages
- Process safety: In case of average, dosing medium does not escape to the environment or into the pump gear, thanks to double diaphragm with diaphragm failure indication.
- Reliable operation thanks to automatic bleeding.
- Protection of the pump against overload with integrated relief valve.
- High process quality: reproducible dosing accuracy better than ±2 %
- Easy handling: direct adjustment and control of dosing capacity in plain language via the big illuminated LC display (Control Version)
- Problem-free connection to complex process control systems with optional equipment with PROFIBUS®-DP interface (Control Version)
- Simplified spare parts management and decreased stock handling efforts at same availability of pumps within the Sigma product line.
- Less training efforts for operating staff when handling the Sigma product line, thanks to same operation modus.
Application Areas
-
Quantity-proportional chemical addition in water treatment, e.g. Sodium Hypochlorite for drinking water disinfection.
-
Measurement-dependent chemical addition, e.g. acid and brine dosing for pH neutralization in waste water treatment
-
Pulse-controlled dosing when bottling different volumina.
Features
- Capacity range 145 - 1.030 l/h, 4 - 12 bar
- High-strength inner housing for energy-stressed components as well as additional polymer housing as protection against corrosion.
- Stroke length: 6 mm, adjustable via self-arresting adjusting knob in 0.5 % steps.
- Double diaphragm with diaphragm failure indication (optionally, also retrofittable), i.e. even with diaphragm failure the dosing medium may not escape uncontrollably from the pump or get into the gear area of the pump.
- Liquid end materials: PVDF, stainless steel 1.4404
- Reproducible dosing accuracy at defined conditions and correct installation better than ±2 % (stroke length area 30-100 %).
- Integrated hydraulic relief valve: protection of the pump against overload without complex extra installations and costs as well as problem-free bleeding of metering pump during suction process.
Features Basic type (S3Ba)
- Borad selection of drive versions: three-phase norm motor, single-phase alternating current motor, motors for the use in EXe and EXde areas, various flange versions for the use of customer-specific motors.
- Protection class IP 55 (optionally ATEX-T3/T4)
- Stroke-length adjustment: manually (optionally with stroke positioning drive or with stroke control drive)
Features Control Version (S3Ca)
- Microprocessor control: optimum combination of variable AC frequency combined with digital stroking frequency, ensures exact metering even in the lower minimum range due to individual stroke control.
- The individual pump functions are simply adjusted using the five programming keys.
- Big backlit LC Display
- Indication in plain language of metering capacity in l/h or US-gal/h
- 3-LED-function as operation indicator, alarm indicator and fault indicator
- Control via contact or analogue signals (e.g. 0/4-20 mA)
- On demand, integration of 2-week-process timer. The intelligent alternative to clock timers.
- Protection class IP 65
- Interface for PROFIBUS®-DP

Technical Data
|
|
at 50 |
at 60 Hz |
|
|
|
Pump type S3Ba / S3Ca |
bar |
l/h |
strokes/min. |
psi |
l/h/gph |
strokes/min. |
suction lift mWS |
connector dimensions G-DN |
|
120145 PVT |
10 |
145 |
72 |
145 |
174/46 |
86 |
5 |
1½-25 |
|
120145 SST |
12 |
145 |
72 |
174 |
174/46 |
86 |
5 |
1½-25 |
|
120190 PVT |
10 |
190 |
103 |
145 |
228/60,2 |
124 |
5 |
1½-25 |
|
120190 SST |
12 |
190 |
103 |
174 |
228/60,2 |
124 |
5 |
1½-25 |
|
120270 PVT |
10 |
270 |
144 |
145 |
324/85,6 |
173 |
5 |
1½-25 |
|
120270 SST |
12 |
270 |
144 |
174 |
324/85,6 |
173 |
5 |
1½-25 |
|
120330 PVT * |
10 |
330 |
180 |
145 |
- |
- |
5 |
1½-25 |
|
120330 SST * |
12 |
330 |
180 |
174 |
- |
- |
5 |
1½-25 |
|
070410PVT |
7 |
410 |
72 |
100 |
492/130 |
86 |
4 |
2-32 |
|
070410 SST |
7 |
140 |
72 |
100 |
492/130 |
86 |
4 |
2-32 |
|
070580 PVT |
7 |
580 |
103 |
100 |
696/183,9 |
124 |
4 |
2-32 |
|
070580 SST |
7 |
580 |
103 |
100 |
696/183,9 |
124 |
4 |
2-32 |
|
040830 PVT |
4 |
830 |
144 |
58 |
1000/264 |
173 |
3 |
2-32 |
|
040830 SST |
4 |
830 |
144 |
58 |
1000/264 |
173 |
3 |
2-32 |
|
041030 PVT * |
4 |
1030 |
180 |
58 |
- |
- |
3 |
2-32 |
|
041030 SST * |
4 |
1030 |
180 |
58 |
- |
- |
3 |
2-32 |
* Only available for S3Ba. For S3Ca Pump types please see 60 Hz-capacity data.
Materials in Contact with Chemicals at Liquid End Version
|
Material |
Liquid End |
Suction/Discharge Connector |
Seals |
Balls (DN 25) |
Panel/ Spring (DN 32) |
Integrated Pressure Relief Valve |
|
PVT |
PVDF (Polyvinylidene- fluoride) |
PVDF (Polyvinylidene- fluorid) |
PTFE |
Glass |
Ceramic/ Hast.C + CTFE |
PVDF/FPM* |
|
SST |
Stainless Steel 1.4404 |
Stainless Steel 1.4404 |
PTFE |
Stainless Steel |
Ceramic 1.4404/ Hast.C |
Stainless Steel/FPM* |
*FPM: Flouric caoutchouc |