5-200 g/h chlorine dioxide. Max. flow at 0.2 ppm ClO2 metering is 1,000 m3/h
Chlorine dioxide system, which continuously produces ClO2 according to the acid/chlorite method with diluted chemicals. Extremely simple operation, clear construction, analogue control, manual control or via contacts.
Product description
Bello Zon CDEb impresses customers with its simple operation and clear construction.
A ready-to-use chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary system for the continuous production and metering of chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary with diluted chemicals. The emphasis is on simple operation and clearly laid out system design with standard components.
The stroke lengths of the metering pumps are continuously monitored. This rules out inadmissible operating statuses arising from incorrect pump stroke length adjustments.
The system is extremely easy to operate and, alongside a central Start-Stop key, also has colour-differentiated LEDs to display all the operating statuses.
The system can be controlled in an analogue or manual manner or via contacts
Your benefits
- Minimal training required thanks to extremely simple operation
- Low investment costs
- Short delivery times
- Simple process integration
Field of application
The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.
- Municipal potable water and wastewater treatment
- Industrial process and cooling water
- Disinfection in the food and beverage industry
Technical Details
- Power supply
- 100-230 V, 50/60 Hz
- Inputs
- 1 digital input for the Pause function
- 1 digital input for contact water meter 0.25-20 Hz
- 1 analogue input 0/4-20mA
- Outputs
- 1 alarm signal relay
- 1 warning signal relay
- Operating substances
- 7.5% sodium chlorite, purity according to EN 938
- 9% hydrochloric acid, purity according to EN 939
- Particle-free water
- Degree of protection
- IP 54
- Bypass pipework
- DN 20
Technical Data
Type | Chlorine dioxide metering rate (min.…max./hour, min./day)* | Max. operating pressure** | Operating temperature | Connection dimensions of chlorite and acid metering pumps | Dimensions H x W x D | Dimensions of the bypass connector | Weight | |
---|---|---|---|---|---|---|---|---|
g/h | g/d | bar | °C | mm | DN | kg | ||
* The metering figures relate to 5 bar back pressure and an ambient temperature of 20 °C. The minimum capacity per hour is based on the fact that when the system is operating at below 10% of the nominal capacity, continuous metering is no longer possible due to the fact that the metering pumps then have a low pumping frequency. Where systems are operating continuously, the reactor content should be changed at least 2 x daily. Therefore, do not operate the system below the stated minimum capacity/day. | ||||||||
** Plus 2 bar from the resistance of the spring-loaded check valves = 10 bar (pump spring) | ||||||||
*** 8 bar at maximum 35 °C ambient temperature | ||||||||
CDEb 30 | 5…30 | 10 | 7 / 8 *** | 15…40 | 6x4 | 958 x 700 x 250 | 20 | 23 |
CDEb 75 | 10…75 | 20 | 7 / 8 *** | 15…40 | 6x4 | 958 x 700 x 250 | 20 | 24 |
CDEb 200 | 20…200 | 40 | 7 / 8 *** | 15…40 | 8x5 | 958 x 700 x 250 | 20 | 27 |
Order no. | |
---|---|
CDEb 30 | 1079438 |
CDEb 75 | 1079439 |
CDEb 200 | 1079440 |
Scope of supply:
Bello Zon CDEb systems are supplied connection-ready on a wall panel. Connection to the site bypass line is via DN 20 PVC threaded connectors with straight solvent unions. Order suction lances for the chemical pumps, safety collecting pans for the chemical drums and other accessories, like flushing equipment with a vacuum relief valve separately.
Downloads for Chlorine Dioxide System Bello Zon CDEb
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Overview
Bello Zon CDEb impresses customers with its simple operation and clear construction.
A ready-to-use chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary system for the continuous production and metering of chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary with diluted chemicals. The emphasis is on simple operation and clearly laid out system design with standard components.
The stroke lengths of the metering pumps are continuously monitored. This rules out inadmissible operating statuses arising from incorrect pump stroke length adjustments.
The system is extremely easy to operate and, alongside a central Start-Stop key, also has colour-differentiated LEDs to display all the operating statuses.
The system can be controlled in an analogue or manual manner or via contacts
Your benefits
- Minimal training required thanks to extremely simple operation
- Low investment costs
- Short delivery times
- Simple process integration
Application
Field of application
The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.
- Municipal potable water and wastewater treatment
- Industrial process and cooling water
- Disinfection in the food and beverage industry
Technical Data
Technical Details
- Power supply
- 100-230 V, 50/60 Hz
- Inputs
- 1 digital input for the Pause function
- 1 digital input for contact water meter 0.25-20 Hz
- 1 analogue input 0/4-20mA
- Outputs
- 1 alarm signal relay
- 1 warning signal relay
- Operating substances
- 7.5% sodium chlorite, purity according to EN 938
- 9% hydrochloric acid, purity according to EN 939
- Particle-free water
- Degree of protection
- IP 54
- Bypass pipework
- DN 20
Technical Data
Type | Chlorine dioxide metering rate (min.…max./hour, min./day)* | Max. operating pressure** | Operating temperature | Connection dimensions of chlorite and acid metering pumps | Dimensions H x W x D | Dimensions of the bypass connector | Weight | |
---|---|---|---|---|---|---|---|---|
g/h | g/d | bar | °C | mm | DN | kg | ||
* The metering figures relate to 5 bar back pressure and an ambient temperature of 20 °C. The minimum capacity per hour is based on the fact that when the system is operating at below 10% of the nominal capacity, continuous metering is no longer possible due to the fact that the metering pumps then have a low pumping frequency. Where systems are operating continuously, the reactor content should be changed at least 2 x daily. Therefore, do not operate the system below the stated minimum capacity/day. | ||||||||
** Plus 2 bar from the resistance of the spring-loaded check valves = 10 bar (pump spring) | ||||||||
*** 8 bar at maximum 35 °C ambient temperature | ||||||||
CDEb 30 | 5…30 | 10 | 7 / 8 *** | 15…40 | 6x4 | 958 x 700 x 250 | 20 | 23 |
CDEb 75 | 10…75 | 20 | 7 / 8 *** | 15…40 | 6x4 | 958 x 700 x 250 | 20 | 24 |
CDEb 200 | 20…200 | 40 | 7 / 8 *** | 15…40 | 8x5 | 958 x 700 x 250 | 20 | 27 |
Order no. | |
---|---|
CDEb 30 | 1079438 |
CDEb 75 | 1079439 |
CDEb 200 | 1079440 |
Scope of supply:
Bello Zon CDEb systems are supplied connection-ready on a wall panel. Connection to the site bypass line is via DN 20 PVC threaded connectors with straight solvent unions. Order suction lances for the chemical pumps, safety collecting pans for the chemical drums and other accessories, like flushing equipment with a vacuum relief valve separately.
Downloads
Downloads for Chlorine Dioxide System Bello Zon CDEb
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.