Suggestions

UV System DULCODES A

Flow up to 809 m3/h

The UV system works cleanly and with efficient use of energy, based on continuously variable medium pressure lamps, and can therefore automatically compensate for variations in the water quality or level of contamination.

Product description

Perfect for the treatment of higher flows.

For the disinfection of drinking water, elimination of chlorine, chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary and ozone Significantly less environmentally harmful by-products result from the generation and use of ozone ... more in the glossary, or for the breaking down of combined chlorine Mono-, di-, trichloroamine. The measuring result of type CLE (free chlorine) is subtracted from the ... more in the glossary in swimming pool water. The Powerline medium-pressure lamps safely inactivate pathogenic organisms. In particular, chlorine-resistant germs, such as cryptosporidia or giardia, are reliably eliminated.

The system is equipped with electronic ballasts, which continuously adjust the lamp output, either via an external signal, such as the flow rate, or by specification of a setpoint.

A long-term stable UVC sensor ensures that the system operates safely and reliably. The motor-driven automatic wiper efficiently cleans the lamp protection tubes and minimises maintenance work with types of water that have a tendency to form films. After comprehensive certification and biodosimetric validation, the systems comply with strict internationally recognised NSF, UL, CSA and USEPA standards.

Your benefits

  • Simple installation, thanks to the compact inline system, ensures minimal installation work and fast retrofitting
  • Maximum flexibility when installing thanks to the free choice of fitting position and direct installation in plastic pipes as no UV radiation escapes from the reactor
  • External power control via 0/4 - 20 mA standard signal for optimum adaptation of the system to changing operating conditions, such as flow fluctuations
  • Automatic adjustment of the lamp output to a defined UVC sensor signal with an increase in power to a raised, adjustable sensor signal via a digital input saves energy and extends the lamp service life.
  • Unbeatably simple and quick maintenance: all maintenance work can be carried out quickly and conveniently from one side.
  • Certified systems: NSF 50, CSA 22, UL508, comprehensively biodosimetric validated to UVDGM 2006

Field of application

The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.

  • Potable water
  • Process water
  • Swimming pool water

    Technical Details

    • Radiation chambers made of high-grade stainless steel 1.4404/AISI316L
    • Guaranteed (pro rata) lamp service life of 8000 hours
    • UVC sensor with long term stability to monitor the system output
    • Automatic motor-driven wiper for efficient removal of deposits on the lamp protection tube
    • Freely programmable control with backlit display during normal operation (green), warning (yellow) and fault (red), visible from afar too
    • Minimum pressure losses even with high flow volumes
    • Optimised use of energy thanks to large radiation chamber and uniform irradiation of the entire water flow due to optimised system hydraulics.
    • Powerline A medium-pressure lamp with high connecting power of up to 3 kW
    • Integral temperature sensor for monitoring the water temperature in the radiation chamber
    • Double, independent and automatic monitoring of the wiper function by revolution counter and limit switch
    • Control cabinet made of coated steel
    • Large graphic display to show all important operating parameters, such as the UV sensor signal, lamp power consumption, control type and operating status
    • Interfaces and connectors for:
      • Shut-off and rinse valve
      • Control of the feed pump
      • Operating signal relay
      • Warning and alarm relay for UV intensity
      • Collective malfunction alert relay
      • Pause contact
      • Relay for monitoring reactor temperature
      • Temperature monitoring and fault indicating relay for control cabinet temperature
      • Input for external fault
      • Digital input for switch-over to second power stage
      • 4-20 mA standard signal input for flow-dependent lamp control or control dependent on measured value
      • Standard signal output 4-20 mA of UV sensor signal

    Technical Data

    Type

    Max. flow rate

    Lamp power

    Connected load

    Radiation chamber length

    Free space needed for maintenance

    Min. distance from wall

    Empty weight/Operating weight

    Connector width

    m3/h

    W

    kW

    mm

    mm

    mm

    kg

    DIN / ANSI

    1x1 A

    50*/83**

    1.000

    1.10

    700

    400

    300

    31/47

    DN 100/4"

    1x2 A

    91*/149**

    2.000

    2.10

    700

    500

    300

    38/65

    DN 150/6"

    1x3 A

    176*/290**

    3.000

    3.20

    800

    600

    300

    52/118

    DN 200/8"

    2x2 A

    240*/395**

    4.000

    4.20

    900

    1000

    300

    78/166

    DN 200/8"

    2x3 A

    328*/539**

    6.000

    6.20

    900

    1000

    300

    78/166

    DN 250/10"

    3x3 A

    492*/809**

    9.000

    9.20

    900

    1000

    300

    78/166

    DN 300/12"

    * 98%/cm transmission; 600 J/m2 irradiation intensity for the breakdown of combined chlorine

    ** 98%/cm transmission; 400 J/m2 irradiation dose for disinfection applications

     

    Lamp type

    Powerline A medium-pressure lamp

    Permissible operating pressure

    10 bar for single-lamp systems 1 x 1A - 1 x 3A
    7 bar for multiple-lamp systems 2 x 2A - 3 x 3A

    Permissible ambient temperature

    5…40 °C

    Permissible water temperature

    5…40 °C

    Enclosure rating

    IP54

    Downloads for UV System DULCODES A

    More in the Download Centre

    0 Results
    Filter by document type
    Application Example / Reference (0)
    Brochure / Flyer (0)
    Catalogue (0)
    Certificate / Declaration (0)
    Data Sheet (0)
    Drawing / Dimensional Drawing / 3D (0)
    Exploded View / Spare Parts (0)
    Material Safety Data Sheet (0)
    Operating Instructions (0)
    Others (0)
    Press Release (0)
    Publication / Article (0)
    Software (0)
    Wiring Diagram (0)

    Selected filters:

    Matching downloads

    Sort by Document type
    Load more matches ...
    No more matches available!

    Unfortunately, we did not find an appropriate match.

    All words written correctly?
    Search again with fewer or different search terms?

    Please try again later

    Service Unavailable

    The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

    Overview

    Perfect for the treatment of higher flows.

    For the disinfection of drinking water, elimination of chlorine, chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary and ozone Significantly less environmentally harmful by-products result from the generation and use of ozone ... more in the glossary, or for the breaking down of combined chlorine Mono-, di-, trichloroamine. The measuring result of type CLE (free chlorine) is subtracted from the ... more in the glossary in swimming pool water. The Powerline medium-pressure lamps safely inactivate pathogenic organisms. In particular, chlorine-resistant germs, such as cryptosporidia or giardia, are reliably eliminated.

    The system is equipped with electronic ballasts, which continuously adjust the lamp output, either via an external signal, such as the flow rate, or by specification of a setpoint.

    A long-term stable UVC sensor ensures that the system operates safely and reliably. The motor-driven automatic wiper efficiently cleans the lamp protection tubes and minimises maintenance work with types of water that have a tendency to form films. After comprehensive certification and biodosimetric validation, the systems comply with strict internationally recognised NSF, UL, CSA and USEPA standards.

    Your benefits

    • Simple installation, thanks to the compact inline system, ensures minimal installation work and fast retrofitting
    • Maximum flexibility when installing thanks to the free choice of fitting position and direct installation in plastic pipes as no UV radiation escapes from the reactor
    • External power control via 0/4 - 20 mA standard signal for optimum adaptation of the system to changing operating conditions, such as flow fluctuations
    • Automatic adjustment of the lamp output to a defined UVC sensor signal with an increase in power to a raised, adjustable sensor signal via a digital input saves energy and extends the lamp service life.
    • Unbeatably simple and quick maintenance: all maintenance work can be carried out quickly and conveniently from one side.
    • Certified systems: NSF 50, CSA 22, UL508, comprehensively biodosimetric validated to UVDGM 2006

    Application

    Technical Data

    Downloads

    Contact us

    Yestin Ng

    Managing Director, ProMinent Fluid Controls (M) Sdn Bhd

    »Please send us your request! We will contact you shortly.«

    +603-8068 2578  Send request   

    ProMinent Newsletter - receive latest news, customized for you! subscribe now