For the precise metering of high-viscosity and extremely high-viscosity media even containing solid fractions
ORLITA DR plunger metering pumps (DR 15 to DR 150) are special pumps for high-viscosity and extremely high-viscosity media, which can also contain solids. The pump can be operated within a broad stroke rate range due to its operation without valves.
Your benefits
Optimum adaptation to processes with high-viscosity and extremely high-viscosity media, even containing solid fractions:
- Low-wear and precise operation even at high pressures thanks to the rotary piston with abrasion-resistant / wear-resistant surface coating
- Valve-free operation guarantees a broad stroke rate range
- Wide range of uses: Operating pressure of up to 400 bar, temperature range of - 40 °C to + 400 °C
- Pumping direction can be selected depending on the fitting position of the piston
- A reverse suction effect can be set in a continuously variable manner by rotating the pump head around its longitudinal axis
- Drive configuration ideal for installation in any position (vertical or horizontal)
Field of application
The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.
- Metering of high-viscosity and extremely high-viscosity media containing solid fractions.
Technical Details
- DR 15 - stroke length: 0-15 mm, Rod force: 1,800 N
- DR 150 - stroke length: 0-32 mm, Rod force: 15,000 N
- Stroke length adjustment range: 0 – 100% in operation and idle
- Stroke length adjustment: manually by means of a manual adjustment wheel and scaled display (optionally with electric actuator or control drive)
- Metering reproducibility is better than ± 0.5% within the stroke length adjustment range of 10 to 100% under defined conditions and with proper installation
- Wetted materials: Stainless steel, special designs are available on request
- A wide range of drive versions is available: Three-phase AC standard motors, motors for use in areas at risk from explosion and different flange designs for use in customer-specific motors
- Degree of protection: IP 55
- Temperature range - 40 °C to + 400 °C
- The play between the piston and cylinder responsible for the sealing effect is selected depending on the viscosity
- Turret on the rear head end, either designed as a circular collecting vessel for leaks or exposed to a sealing medium
- The turret is sealed by elastomer lip sealing rings
Technical data for ORLITA DR 15 single-head pump 50 Hz
Plunger Ø | Theor. stroke volume | Max. capacity (theo.) in l/h at strokes/min (50 Hz) | Max. pressure | Standard type of valve |
---|
| | 58 | 77 | 116 | | |
---|
mm | ml/stroke | l/h | l/h | l/h | bar |
|
---|
7 | 0.58 | 2.0 | 2.7 | 4.0 | 400 | DN 8 |
12 | 1.70 | 5.9 | 7.9 | 11.8 | 400 | DN 8 |
18 | 3.82 | 13.3 | 17.7 | 26.6 | 250 | DN 16 |
25 | 7.36 | 25.6 | 34.1 | 51.2 | 147 | DN 25 |
36 | 15.27 | 53.1 | 70.8 | 106.3 | 76 | DN 32 |
Technical data for ORLITA DR 150 single-head pump 50 Hz
Plunger Ø | Theor. stroke volume | Theoretical pump capacity in l/h at strokes/min | Max. pressure | Standard type of valve |
---|
| | 70 | 94 | 141 | | |
---|
mm | ml/stroke | l/h | l/h | l/h | bar |
|
---|
12 | 3.62 | 15.2 | 20.3 | 30.4 | 400 | DN 8 |
18 | 8.14 | 34.2 | 45.6 | 68.4 | 400 | DN 8 |
25 | 15.71 | 66.0 | 87.9 | 131.9 | 250 | DN 16 |
36 | 32.57 | 136.8 | 182.3 | 273.6 | 147 | DN 25 |
Note
All performance data applies to 50 Hz. If a 60 Hz motor is used, the performance will be correspondingly higher.
Abridged presentation of our complete product range. Other types on request.