Suggestions

Plunger Metering Pump ORLITA DR

Capacity range of single-head pump: 0 – 2000 l/h, 400 – 5 bar

The plunger metering pump ORLITA DR does not need valves and can therefore be operated within a broad stroke rate range. It is therefore suitable for use with high-viscosity and extremely high-viscosity media of up to 106 mPas within a wide temperature range of -40 °C to 400 °C.

Product description

For the precise metering of high-viscosity and extremely high-viscosity media even containing solid fractions

ORLITA DR plunger metering pumps (DR 15 to DR 150) are special pumps for high-viscosity and extremely high-viscosity media, which can also contain solids. The pump can be operated within a broad stroke rate range due to its operation without valves.

Your benefits

Optimum adaptation to processes with high-viscosity and extremely high-viscosity media, even containing solid fractions:

  • Low-wear and precise operation even at high pressures thanks to the rotary piston with abrasion-resistant / wear-resistant surface coating
  • Valve-free operation guarantees a broad stroke rate range
  • Wide range of uses: Operating pressure of up to 400 bar, temperature range of - 40 °C to + 400 °C
  • Pumping direction can be selected depending on the fitting position of the piston
  • A reverse suction effect can be set in a continuously variable manner by rotating the pump head around its longitudinal axis
  • Drive configuration ideal for installation in any position (vertical or horizontal)

Field of application

The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.

  • Metering of high-viscosity and extremely high-viscosity media containing solid fractions.

    Technical Details

    • DR 15 - stroke length: 0-15 mm, Rod force: 1,800 N
    • DR 150 - stroke length: 0-32 mm, Rod force: 15,000 N
    • Stroke length adjustment range: 0 – 100% in operation and idle
    • Stroke length adjustment: manually by means of a manual adjustment wheel and scaled display (optionally with electric actuator or control drive)
    • Metering reproducibility is better than ± 0.5% within the stroke length adjustment range of 10 to 100% under defined conditions and with proper installation
    • Wetted materials: Stainless steel, special designs are available on request
    • A wide range of drive versions is available: Three-phase AC standard motors, motors for use in areas at risk from explosion and different flange designs for use in customer-specific motors
    • Degree of protection: IP 55
    • Temperature range - 40 °C to + 400 °C
    • The play between the piston and cylinder responsible for the sealing effect is selected depending on the viscosity
    • Turret on the rear head end, either designed as a circular collecting vessel for leaks or exposed to a sealing medium
    • The turret is sealed by elastomer lip sealing rings

    Technical data for ORLITA DR 15 single-head pump 50 Hz

    Plunger Ø

    Theor. stroke volume

    Max. capacity (theo.) in l/h at strokes/min (50 Hz)

    Max. pressure

    Standard type of valve

    58

    77

    116

    mm

    ml/stroke

    l/h

    l/h

    l/h

    bar

    7

    0.58

    2.0

    2.7

    4.0

    400

    DN 8

    12

    1.70

    5.9

    7.9

    11.8

    400

    DN 8

    18

    3.82

    13.3

    17.7

    26.6

    250

    DN 16

    25

    7.36

    25.6

    34.1

    51.2

    147

    DN 25

    36

    15.27

    53.1

    70.8

    106.3

    76

    DN 32

    Technical data for ORLITA DR 150 single-head pump 50 Hz

    Plunger Ø

    Theor. stroke volume

    Theoretical pump capacity in l/h at strokes/min

    Max. pressure

    Standard type of valve

    70

    94

    141

    mm

    ml/stroke

    l/h

    l/h

    l/h

    bar

    12

    3.62

    15.2

    20.3

    30.4

    400

    DN 8

    18

    8.14

    34.2

    45.6

    68.4

    400

    DN 8

    25

    15.71

    66.0

    87.9

    131.9

    250

    DN 16

    36

    32.57

    136.8

    182.3

    273.6

    147

    DN 25

    Note

    All performance data applies to 50 Hz. If a 60 Hz motor is used, the performance will be correspondingly higher.

    Abridged presentation of our complete product range. Other types on request.

    Downloads for Plunger Metering Pump ORLITA DR

    More in the Download Centre

    0 Results
    Filter by document type
    Application Example / Reference (0)
    Brochure / Flyer (0)
    Catalogue (0)
    Certificate / Declaration (0)
    Data Sheet (0)
    Drawing / Dimensional Drawing / 3D (0)
    Exploded View / Spare Parts (0)
    Material Safety Data Sheet (0)
    Operating Instructions (0)
    Others (0)
    Press Release (0)
    Publication / Article (0)
    Software (0)
    Wiring Diagram (0)

    Selected filters:

    Matching downloads

    Sort by Document type
    Load more matches ...
    No more matches available!

    Unfortunately, we did not find an appropriate match.

    All words written correctly?
    Search again with fewer or different search terms?

    Please try again later

    Service Unavailable

    The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

    Overview

    For the precise metering of high-viscosity and extremely high-viscosity media even containing solid fractions

    ORLITA DR plunger metering pumps (DR 15 to DR 150) are special pumps for high-viscosity and extremely high-viscosity media, which can also contain solids. The pump can be operated within a broad stroke rate range due to its operation without valves.

    Your benefits

    Optimum adaptation to processes with high-viscosity and extremely high-viscosity media, even containing solid fractions:

    • Low-wear and precise operation even at high pressures thanks to the rotary piston with abrasion-resistant / wear-resistant surface coating
    • Valve-free operation guarantees a broad stroke rate range
    • Wide range of uses: Operating pressure of up to 400 bar, temperature range of - 40 °C to + 400 °C
    • Pumping direction can be selected depending on the fitting position of the piston
    • A reverse suction effect can be set in a continuously variable manner by rotating the pump head around its longitudinal axis
    • Drive configuration ideal for installation in any position (vertical or horizontal)

    Application

    Technical Data

    Downloads

    Contact us

    Yestin Ng

    Managing Director, ProMinent Fluid Controls (M) Sdn Bhd

    »Please send us your request! We will contact you shortly.«

    +603-8068 2578  Send request   

    ProMinent Newsletter - receive latest news, customized for you! subscribe now